The Separ 2000 Series is a line of fuel water separators that are designed to accommodate newer and more demanding diesel engines. They are manufactured from high quality, non-corroding aluminum alloy castings, heavy polycarbonate or metal bowls and stainless steel hardware. Fuel systems are protected and engine failure is avoided by the filter’s ability to separate harmful particulate and water from diesel fuel.
2000/5
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 -Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-2000550.png)
2000/5/50
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .53 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-2000550K.png)
2000/5/50K
Technical Specifications
- Maximum Flow Performance: – 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .53 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/2000550U.png)
2000/5/50U
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 15mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .53 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/2000550UMK.png)
2000/5/50UMK
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 15mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .53 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-20005K.png)
2000/5K
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-20005M.png)
2000/5M
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-20005MK.png)
2000/5MK
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 1/2″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/20005U.png)
2000/5U
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 12 mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/20005UMK.png)
2000/5UMK
Technical Specifications
- Maximum Flow Performance: 79 GPH / 300 LPH
- Inlet/Outlet: 12 mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .59 in. Hg.
- Maximum Allowable Pressure: 15 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-200010-1.png)
2000/10
Technical Specifications
- Maximum Flow Performance: 158 GPH / 600 LPH
- Inlet/Outlet: 5/8″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .31 in. Hg.
- Maximum Allowable Pressure: 12 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-200010K.png)
2000/10K
Technical Specifications
- Maximum Flow Performance: 158 GPH / 600 LPH
- Inlet/Outlet: 5/8″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .31 in. Hg.
- Maximum Allowable Pressure: 12 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-200010M.png)
2000/10M
Technical Specifications
- Maximum Flow Performance: 158 GPH / 600 LPH
- Inlet/Outlet: 5/8″ Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .31 in. Hg.
- Maximum Allowable Pressure: 12 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200010U.png)
2000/10U
Technical Specifications
- Maximum Flow Performance: 158 GPH / 600 LPH
- Inlet/Outlet: 15mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .31 in. Hg.
- Maximum Allowable Pressure: 12 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200010UMK.png)
2000/10UMK
Technical Specifications
- Maximum Flow Performance: 158 GPH / 600 LPH
- Inlet/Outlet: 15mm with 1/2 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .31 in. Hg.
- Maximum Allowable Pressure: 12 bar
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-200018.png)
2000/18
Technical Specifications
- Single 285 GPH Fuel Water Separator with Clear Bow
![](https://genclean.ca/wp-content/uploads/2021/05/cropped-200018K.png)
2000/18K
Technical Specifications
- Single 285 GPH Fuel Water Separator with Clear Bow
![](https://genclean.ca/wp-content/uploads/2021/05/200018U.png)
2000/18U
Technical Specifications
- Duplex 285 GPH Fuel Water Separator with Clear Bow
![](https://genclean.ca/wp-content/uploads/2021/05/200018UK.png)
2000/18UK
Technical Specifications
- Maximum Flow Performance: 285 GPH / 1080 LPH
- Inlet/Outlet: 22mm with 3/4 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .44 in. Hg.
- Maximum Allowable Pressure: 7 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200018UM.png)
2000/18UM
Technical Specifications
- Maximum Flow Performance: 285 GPH / 1080 LPH
- Inlet/Outlet: 22mm with 3/4 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .44 in. Hg.
- Maximum Allowable Pressure: 7 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200018UMK.png)
2000/18UMK
Technical Specifications
- Maximum Flow Performance: 285 GPH / 1080 LPH
- Inlet/Outlet: 22mm with 3/4 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .44 in. Hg.
- Maximum Allowable Pressure: 7 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200040MK-Gray-Metric.png)
2000/40MK
Technical Specifications
- Maximum Flow Performance: 634 GPH / 2400 LPH
- Inlet/Outlet: Metric M33x2 Female O-ring Boss
- Restriction at Maximum Flow and 30 Micron Element: .95 in. Hg.
- Maximum Allowable Pressure: 4 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200040UMK.png)
2000/40UMK
Technical Specifications
- Maximum Flow Performance: 634 GPH / 2400 LPH
- Inlet/Outlet: 35mm with 1 1/4 Male JIC Flare Fittings
- Restriction at Maximum Flow and 30 Micron Element: .95 in. Hg.
- Maximum Allowable Pressure: 4 bar
![](https://genclean.ca/wp-content/uploads/2021/05/200018UMK.png)
2000/130MK-G
Technical Specifications
- Maximum Flow Performance: 2,060 GPH / 7800 LPH
- Inlet/Outlet: 2 NPT Pipe
- Restriction at Maximum Flow and 30 Micron Element: .95 in. Hg.
- Maximum Allowable Pressure: 2 bar